JESD204B
JESD204B is a revision of the JEDEC standard Serial Interface for Data Converters (document number JESD204), which connects data converters (analog-to-digital converters and digital-to-analog converters) to logic devices such as FPGAs, ASICs and DSPs over a high-speed serial link.[1] JESD204B, the second revision, appeared in July 2011.[2] It raises the maximum lane rate to 12.5 Gbit/s and adds deterministic, repeatable latency across the link.[3]
Background and revisions
[edit]JESD204 needs fewer interconnects between converter and logic device than parallel CMOS or LVDS interfaces, which simplifies printed circuit board layout.[1] The revisions up to B are:
- JESD204 (2006): one lane, one converter, up to 3.125 Gbit/s.
- JESD204A (2008): multiple lanes and converters, up to 3.125 Gbit/s.
- JESD204B (2011): up to 12.5 Gbit/s per lane, deterministic latency, device subclasses, and a common device clock distributed to all devices, from which each derives its frame and multiframe clocks.[2]
JESD204C (2017) raised the lane rate to 32.45 Gbit/s and added 64b/66b and 64b/80b link layers. It does not replace JESD204B. It stays backward compatible and retains the 8b/10b link layer as a normative option alongside the newer encodings.[3]
Technical characteristics
[edit]The link is a point-to-point serial connection over differential lanes driven with current-mode logic (CML), the signalling used by the multi-gigabit transceivers (SerDes) in FPGAs and ASICs. 8b/10b encoding embeds the clock in the data stream, so no separate clock line is needed, and the payload may optionally be scrambled.[1] A link uses up to 32 lanes.
Functionality spans three layers. A transport layer maps converter samples into frames, a data link layer handles encoding, synchronisation and lane alignment, and a physical layer (PHY) drives the serial lanes. A link is defined by parameters including the number of lanes (L), converters (M), octets per frame (F), samples per converter per frame (S), converter resolution (N), word width (Nâ˛) and frames per multiframe (K).[2] At startup the lanes are aligned by the Initial Lane Alignment Sequence (ILAS) using defined 8b/10b control characters.[1]
Frame structure and lane rate
[edit]Converter samples are organised into a nested structure of octets, frames and multiframes. An octet is 8 bits. A sample word of NⲠbits carries the converter's N bits plus optional control and tail bits, and NⲠis normally padded to a multiple of 4 bits (a nibble) rather than a full octet, so a 12 bit converter can use NⲠ= 12. A frame is F octets per lane spanning one frame clock period and carrying S samples per converter. A multiframe is K frames and forms the unit for alignment and timing. Its boundary comes from the local multiframe clock, which SYSREF (or SYNC~) resets for deterministic latency.[2]
The lane rate follows from these parameters and the 8b/10b overhead.
where M is the number of converters, NⲠthe bits per sample, fs the sample rate and L the number of lanes, the factor 10/8 covering 8b/10b line coding. For example, a converter device with four 14 bit converters (NⲠ= 16), each at 500 MSPS, over eight lanes needs 5 Gbit/s per lane.[4]
Deterministic latency and subclasses
[edit]Unlike its predecessors, JESD204B keeps interface latency repeatable across power cycles and re-synchronisations.[5] It introduces the SYSREF signal as a timing reference that aligns the per-device clock dividers, the local multiframe clock. Three device subclasses are defined:[2][5]
- Subclass 0: no deterministic latency, equivalent to JESD204A.
- Subclass 1: deterministic latency via SYSREF.
- Subclass 2: deterministic latency via SYNC~.
Subclasses 1 and 2 reach the same deterministic latency by different signals, differing in the usable device-clock range rather than in achievable precision.[2] An informative annex of the standard recommends a Subclass 1 (SYSREF) approach for device-clock rates above about 500 MHz.[6]
Deterministic latency matters where downstream processing needs a fixed time-of-flight from the analogue front end, or where multiple converter devices must be sample-aligned, as in multi-channel and beamforming receivers.[7]
Applications
[edit]The interface is used mainly in high-throughput systems such as wireless communications, radar, test and measurement, and medical imaging.[1]
References
[edit]- 1 2 3 4 5 Harris, Jonathan (2013). JESD204B Survival Guide (PDF) (Technical report). Analog Devices. Retrieved 2026-07-01.
- 1 2 3 4 5 6 JEDEC Solid State Technology Association (July 2011). JESD204B: Serial Interface for Data Converters (Technical report). JEDEC. JESD204B.
- 1 2 Texas Instruments (2020). What to Know About the Differences Between JESD204B and JESD204C (Technical report). SBAA517. Retrieved 2026-07-01.
- â "JESD204 documentation (Lane rate math)". Retrieved 2026-07-01.
- 1 2 Beavers, Ian (2014). Demystifying Deterministic Latency Within JESD204B Converters (Technical report). Analog Devices. MS-2626. Retrieved 2026-07-01.
- â JEDEC Solid State Technology Association (July 2011). JESD204B: Serial Interface for Data Converters (Technical report). JEDEC. Annex B (informative). JESD204B.
- â Bellato, M.; et al. (2017). "A JESD204B-Compliant Architecture for Remote and Deterministic-Latency Operation". IEEE Transactions on Nuclear Science. doi:10.1109/TNS.2017.2655569.