A power supply can be tested at home four ways: a paperclip start, a PSU tester, a multimeter and software readings under load. Each answers a different question, and none of them can clear ripple or closed-loop stability, which Intel’s ATX 3.0 design guide lists as required, or hold-up time, which the guide labels REQUIRED/RECOMMENDED. The start test follows Corsair’s paperclip procedure, which bridges pins 16 and 17 with only AC and the 24-pin connector attached. This page was refreshed on 13 November 2026: the paperclip pins, the 12V-2×6 bend distance and the rail windows are corrected, and the ATX 3.1 cable advice is added.
Don't miss new tech stories on Google
Add Tech Insider once in the Google app and our stories appear in your news suggestions.
Start with the symptom: which first test fits a dead PC and which fits a GPU-load reboot
Rule out the free causes first: a working wall outlet, the rear switch set to on, and the 24-pin and CPU power cables pushed fully home at both ends. Then shut down, switch the PSU off, pull the wall cable and hold the case power button for a few seconds before opening anything. If you smell burning or see a scorched or melted pin, stop: replace the unit and the damaged cable without testing.
Leave the PSU’s own case closed. Corsair’s power supply manual tells owners not to open the case or attempt a repair because “there are no user-serviceable components.” A unit that fails a test is replaced or sent for RMA.
| Symptom | First test | What a result tells you |
|---|---|---|
| No fans, no lights, no POST | Paperclip start | If the PSU starts, look at the board, RAM or front-panel lead next. If it does not, check outlet and rear switch, then suspect the PSU. |
| Boots, then reboots only under GPU load | Multimeter or software while a stress test runs, then the 12V-2×6 or PCIe cable | A rail leaving its window under load points at the PSU. A clean rail points at the cable, GPU, RAM or drivers. |
| Fails after a GPU or storage upgrade | Rail check under load | Compare the load readings with the PSU’s rated wattage and available connectors. |
| Burning smell, scorched or melted connector | None | Stop and replace. |
What each home test can see against Intel’s required list
Intel’s guide marks over-voltage, short-circuit, no-load, over-current and over-temperature protection as REQUIRED. It does the same for output ripple and noise, closed-loop stability, +5V/+3.3V power sequencing, PWR_OK, PS_ON#, +5VSB, power-on time, rise time and turn-on/turn-off overshoot. Voltage hold-up time is labelled REQUIRED/RECOMMENDED on the guide’s reference page (checked 13 November 2026), and capacitive load is only RECOMMENDED. The page carries the notice “A newer version of this document is available”, so the table below is keyed to the 3.0 guide (document 336521).
| Intel list item | Paperclip | Tester | Multimeter | Software |
|---|---|---|---|---|
| Starts on PS_ON#, power-on time | Shows start or no start | Shows | Shows rails appearing | Hints (system boots) |
| +5VSB standby | Cannot see | Shows | Shows | Hints |
| Rail level, light load | Cannot see | Shows | Shows | Hints |
| Rail level, under load | Cannot see | Cannot see | Shows, if probed during a stress run | Hints |
| PWR_OK, rise time, overshoot, sequencing | Cannot see | Hints | Cannot see | Cannot see |
| Ripple and noise, closed-loop stability, hold-up | Cannot see | Cannot see | Cannot see | Cannot see |
| OVP, SCP, OCP, OTP, no-load behaviour | Cannot see | Cannot see | Cannot see | Cannot see |
The matrix and the rail windows below are our own reading and arithmetic from the cited documents. Ripple, transient response, hold-up and protection events need an oscilloscope, an electronic load and a lab protocol. A home pass narrows the fault but cannot clear the PSU. Do not short or overload a rail to “test” the protections: they are behaviours the unit must handle itself. Server supplies fall under a separate method, ITU-T L.1241 (09/2023), which is outside this page.
PWR_OK is a timing signal that a multimeter cannot resolve. Intel’s timing section says a T3 minimum time faster than 100 ms “is not recommended for previous generation motherboards and systems”. A no-POST with good rails is therefore a reason to try a known-good PSU.
The paperclip start: pins 16 and 17, nothing else connected
Corsair’s page (checked 13 November 2026) says: “Unplug all cables from the PSU except for the main AC cable and the 24-pin cable.” Earlier versions of this page told you to attach a fan or drive and to bridge pin 15 or 17. Neither matches Corsair’s procedure, which uses no extra load. Zero-RPM supplies may spin the fan only briefly, so a short spin is a start, not a fault.
PAPERCLIP START
Set up, in order:
switch the PSU off and unplug AC
unplug every cable except the 24-pin
bridge pin 16 and pin 17 on the 24-pin with a paperclip
plug in AC, switch on
Shut down in reverse:
switch off, unplug AC, remove the paperclip
To find pin 16 and pin 17, count from the left with the clip facing up and the pins facing toward you, as Corsair describes. Do this on a non-conductive surface and never touch the pins while it is energised. A start means the supply responds to the PS_ON# signal Intel lists as required. It says nothing about load, droop or ripple. If it fails to start, recheck the outlet and rear switch, then move to the tester or multimeter to see which rail is missing.
Reading the rails: tester or multimeter, and the windows to judge them by
Fluke describes its electrical testers as covering voltage measurement, continuity and basic current, which is all a rail check needs. Set the meter to DC volts, put the black probe on a ground pin and the red probe on the rail pin, using your PSU’s pinout from its manual. This page judges all four rails against a ±5% window around nominal, and the limits match those listed on Thermaltake’s Dr. Power III Pro page. The earlier edition’s 11.20 V +12V minimum is withdrawn.
| Rail | Nominal | Working window |
|---|---|---|
| +12V | 12 V | 11.40 to 12.60 V |
| +5V | 5 V | 4.75 to 5.25 V |
| +3.3V | 3.3 V | 3.14 to 3.47 V |
| +5VSB | 5 V | 4.75 to 5.25 V |
Log idle and load readings, then compute droop as (idle minus load) divided by nominal. For example, a +12V rail that falls from its 12 V nominal to 11.40 V under load has dropped 0.60 V, or 5% of 12 V, which is exactly the bottom of the window.
Rail Idle (V) Load (V) Droop = (idle minus load) / nominal
+12V ______ ______ ______
+5V ______ ______ ______
+3.3V ______ ______ ______
+5VSB ______ n/a n/a
A tester is optional. Thermaltake’s Dr. Power III Pro has a color display, four rail readouts (+12V, +5V, +3.3V, +5VSB), automatic and manual modes, full PCIe 12+4-pin connector compatibility, 150W, 300W, 450W and 600W sense-signal detection and ATX v3.1 support. Thermaltake says the Dr. Power III Pro detects the SENSE0/SENSE1 sideband signals on the PCIe 12+4-pin connector. If you only need rail levels, a multimeter covers them.
Load, a stress run and a wall meter
Rails that look fine at idle prove little. Run a combined CPU and GPU stress test, probe the same pins while it runs and apply the droop formula.
For crashes that come and go, a short stress run can miss them, and synthetic tests may not reproduce the brief spikes real games produce. The hwinfo.co features page says timestamped CSV logs help tie game crashes, render failures or shutdowns to thermal or power spikes. Log continuously through a full play session, such as two hours, then look for voltage dips that line up with the crash or stutter timestamps.
A wall meter adds a sanity check on the AC side. The 80 PLUS 115V table gives efficiency at three loads (Titanium also carries 90% at 10% load). The last two columns are our calculation at a 400 W DC load and each tier’s 50% point: wall draw is DC load divided by efficiency, and waste heat is wall draw minus 400 W.
| Tier | 20% load | 50% load | 100% load | Wall draw at 400 W DC | Waste heat |
|---|---|---|---|---|---|
| 80 PLUS | 80% | 80% | 80% | 500.0 W | 100.0 W |
| Bronze | 82% | 85% | 82% | 470.6 W | 70.6 W |
| Silver | 85% | 88% | 85% | 454.5 W | 54.5 W |
| Gold | 87% | 90% | 87% | 444.4 W | 44.4 W |
| Platinum | 90% | 92% | 89% | 434.8 W | 34.8 W |
| Titanium | 92% | 94% | 90% | 425.5 W | 25.5 W |
In reverse, DC load is roughly wall watts times efficiency: 500 W at the wall on a Gold unit near its 50% point implies about 450 W of DC load (500 × 0.90). That is an estimate near the certified load points, not a measure of the PSU’s health.
A 12V-2×6 cable: seating, 30 mm and the sense readout
Corsair’s bend guidance (checked 13 November 2026) is: “Keep around 30mm of cable from the connector before a bend.” It also advises avoiding harsh 90° bends where possible. Earlier versions of this page said 35mm. Push the connector in fully. If you use a tester with sense detection, the SENSE0/SENSE1 readout described above is the check on the cable’s signalled power level.
If you replace the unit, Corsair’s RM1200e shows what a current ATX 3.1 supply carries: 1200 W, 80 PLUS Gold, fully modular, ATX 3.1 and PCIe 5.1 compliance and a 12V-2×6 GPU cable in the box.
From reading to verdict
| Finding | Points to | Next step | Still not ruled out |
|---|---|---|---|
| No start on the paperclip test | Outlet, switch, or PSU | Recheck outlet, switch and 24-pin seating; replace or RMA if it repeats | Not applicable |
| A rail outside its window at idle | PSU | Reseat the probe, retest, then RMA or replace | Not applicable |
| In window at idle, outside it under load | PSU cannot hold the rail | RMA if under warranty, otherwise replace | Not applicable |
| Inside every window, crashes continue | Not conclusive | Check RAM and any DDR5 overclock settings, then the GPU and drivers | Ripple, transient response, hold-up, protections, PWR_OK timing |
| Scorched or melted connector | Stop use | Replace the PSU and the cable | Not applicable |
If every test passes and the crashes continue, swap in a known-good PSU if you have one. Ripple, transient response, hold-up and PWR_OK timing can only be cleared with bench equipment, so a swap is the practical home check.