STL (Sterlite Technologies, NSE: STLTECH) announced on 10 September 2026 from Columbia, S.C. that its 48F to 576F Intermittently Bonded Ribbon (IBR) pre-terminated trunk assemblies now carry US OFNP (plenum) certification, according to the PR Newswire release. This page keeps that certification apart from STL’s 6,912F range, announced on 24 September 2026, which is a separate cable.
Don't miss new tech stories on Google
Add Tech Insider once in the Google app and our stories appear in your news suggestions.
What the 10 September release certifies, and the specs STL has published for the cable
The release describes an update to STL’s data center portfolio: OFNP (Optical Fiber Nonconductive Plenum) US certification for the 48 to 576F IBR pre-terminated assembly portfolio. STL says the certification makes it “among the global AI-ready infrastructure providers for NFPA 262-qualified indoor cable assemblies.” It also says the factory-built assemblies arrive with connectors installed, polished and tested, “preventing the need for field splicing.”
On STL’s own page for the release, checked on 12 November 2026, the headline reads “Secures NFPA 262 Compliance for Intermittently Bonded Ribbon (IBR) Portfolio”, so the release names NFPA 262 compliance and the OFNP certification as its standards.
IBR is STL’s patented rollable ribbon technology, and STL’s 24 September Neuralis release pairs it with a colour-coded bonded ribbon design that STL says makes ribbons quicker and more accurate to identify. The table takes diameters, the cable standard and connectors from that release and from EE News Europe’s report of it, and labels each row with its record.
| Parameter | Published value | Source record |
|---|---|---|
| Fiber count | 48F to 576F | 10 September release |
| Certification | US OFNP; NFPA 262-qualified indoor cable assemblies | 10 September release |
| Cable listing options | OFNP plenum or OFNR riser | 24 September release; EE News Europe |
| Cable diameter | 5.8 mm (48F) to 12.2 mm (576F) | 24 September release |
| Standard | ANSI/ICEA S-83-596 | 24 September release |
| Terminations | High-density MMC, MPO and LC; the Neuralis whitespace page adds MTP | EE News Europe; Neuralis whitespace page |
| Ribbon | Patented IBR rollable ribbon, colour-coded bonded ribbon | 24 September release |
| Factory work | Connectors installed, polished and tested; every assembly 100% factory tested | 10 September release; 24 September release |
| Intended use | Indoor hyperscale, colocation and enterprise data center containment zones | 10 September release |
Plenum or riser: when the OFNP listing is the one you need
STL positions the plenum-certified portfolio as “purpose-built for indoor applications,” aimed at hyperscale, colocation and enterprise data center containment zones. It says the cables are optimised for tight routing so operators can scale bandwidth in restricted duct spaces without compromising safety compliance. CTO Dr. Badri Gomatam is quoted saying the physical layer “must evolve to meet unprecedented density and safety demands.”
The same indoor family also comes with OFNR riser-rated cable, per the 24 September release. So the certification widens the choice rather than replacing the riser option. Which listing a given pathway needs is a decision for your designer and the local authority having jurisdiction, not for the vendor.
Read together, the records describe a plenum-listing extension of an existing pre-terminated family, not a new cable technology. STL’s Neuralis data center whitespace page lists the same 48F to 576F range with OFNP (Plenum) and OFNR (Riser) jacket ratings and MMC, MTP, MPO and LC connectors. The news matters mainly to buyers with plenum runs.
Three STL records between May and September 2026, and which cable each one covers
| Date | STL record | What it covers |
|---|---|---|
| May 2026 | US Conec certification, announced by STL Optical Connectivity NA, LLC | Certification to offer pre-terminated fiber trunks using MMC connectors |
| 10 September 2026 | Plenum-rated fiber trunk assemblies release | OFNP US certification for the 48F to 576F IBR pre-terminated portfolio |
| 24 September 2026 | Neuralis pre-terminated trunk assemblies release, reported by EE News Europe | Two families: the indoor 48F to 576F assemblies, and a separate higher-count range whose densest cable carries 6,912 fibers with a 32 mm outer diameter |
The May 2026 record is STL’s US Conec announcement. STL’s US subsidiary, STL Optical Connectivity NA, LLC, said it was certified by US Conec to offer pre-terminated trunks using MMC connectors. That is a connector certification, not a fire listing, and MMC is one of the termination options in the later indoor spec. The plenum release is the only one of the three that is about a fire listing.
STL’s press release listing dates the Neuralis release 24 September 2026, and EE News Europe reports that its 6,912F cable is the highest-density version, with a 32 mm outer diameter. Until STL documents a plenum listing for it, treat 576F as the ceiling for plenum runs.
The savings STL asserts, and what a buyer has to price
The plenum release’s savings argument is that factory termination removes field splicing. EE News Europe’s report of the 24 September release adds that factory termination reduces the need for on-site connector installation and helps operators speed deployment. The plenum release says the factory-built assemblies result in “fast installation and lowered cost.” Its wording is also modest: STL calls itself “among” the providers with NFPA 262-qualified indoor assemblies, which places it as a peer on this listing rather than the only holder.
To test the savings claim, price the on-site labour for splicing, polishing and testing a field-terminated plenum run against the unit price and lead time of the pre-terminated assembly. Then ask the same question of every vendor on the shortlist, for example Corning, CommScope, Panduit or Amphenol, at the same fiber count and listing. A quote for OFNP and a quote for OFNR on the same count will show what the plenum jacket costs.
STL as a supplier: factories on three continents, and the results it reports
In the release, STL says it has manufacturing facilities in North America, Europe and Asia and delivers its solutions in more than 100 countries. For a buyer adding a second source, that footprint is the relevant claim, though it does not say which plant builds the OFNP assemblies, which is why that question is on the list below. STL repeats the footprint in its Q1 FY27 results release, which it titled as record financial performance. The figures in that release, below, are STL’s own reported numbers; they are not in the plenum release and this page has not checked them against audited accounts.
| INR crore | Q1 FY27 | Year-on-year growth |
|---|---|---|
| Revenue | 1,910 | about 87% |
| EBITDA | 397 | about 184% |
Documents to request before OFNP trunks go into a containment spec
- The OFNP listing for each part number you intend to specify, with the name of the listing body and the file number, matched to fiber count and cable diameter.
- The 24 September Neuralis spec sheet for those part numbers, showing the available terminations (MMC, MTP, MPO or LC) on the OFNP cable.
- The test reports behind the “100% factory tested” claim, including the format of the per-assembly results delivered with each order.
- The plant and country that build the OFNP assemblies, and the lead time quoted from that plant.
- Unit price and lead time for the OFNP and OFNR versions of the same fiber count, so the plenum premium and the field-splicing alternative can both be priced.
- Written confirmation of the plenum listing status of any 6,912F run you are considering.