Custom Water-Cooling Loop Build: Radiator Sizing and a Staged Leak Test

The GPU is what justifies a custom loop, and the leak test is the step with the most at stake for the hardware. Custom PC’s leak-testing guide says to raise the whole loop to 0.3 bar and hold it for ten minutes, and this guide adds a longer filled soak, with the board and GPU unpowered, before the PC is powered on normally. The cost question comes first: formulamod prices a CPU-only loop at $150-250 and a CPU-plus-GPU loop at $400-700, so the decision is whether the GPU belongs in the loop at all. The build below runs in 13 steps.

Google · Preferred Sources

Don't miss new tech stories on Google

Add Tech Insider once in the Google app and our stories appear in your news suggestions.

Add Now

Loop or AIO: putting the GPU in the loop is what the extra money buys

An all-in-one cooler cools the CPU only. A custom loop can send coolant through a CPU block and a full-cover GPU block into the same radiators, and that is the case for going custom. On formulamod’s figures, adding the GPU adds about $250 at the low end and $450 at the high end ($400 minus $150, and $700 minus $250). Without the GPU in the loop, the case for a custom build is thin.

SourceWhat it pricesFigure
formulamodBasic CPU-only loop$150-250
formulamodFull CPU+GPU loop with premium components$400-700
wikiHowBasic setup up to high-end enthusiast buildsFrom around $100 to several thousand dollars
Stateline Tech, listing Micro CenterService price for a custom soft-tubing loop build$399.99 (August 2026)
Corsair US product pageOne GPU block, Hydro X Series XG5 RGB 5090 Astral$389.99 (checked November 13, 2026)

Corsair’s US product page lists the Hydro X Series XG5 RGB 5090 Astral block at $389.99 with a three-year warranty and marks it Out Of Stock, as of November 13, 2026. formulamod’s $400-700 range is for a full CPU+GPU loop with premium components. One block at that price is about 98% of the $400 floor (389.99 divided by 400 is 0.975) and leaves about $310 of the $700 ceiling for the pump, reservoir, CPU block, radiators, fans, tubing, fittings and coolant, so price the rest of your list before trusting either end of the range. wikiHow’s range, from around $100 for a basic setup to several thousand dollars for high-end enthusiast builds, is a broad span, so its page is context here and formulamod’s CPU-only versus CPU-plus-GPU split is the one used.

Paying a shop is the other route. Stateline Tech’s survey of what shops charge lists Micro Center’s custom soft-tubing liquid loop build at $399.99 in August 2026. That is a service price, so set it against the hours you would spend on the 13 steps below.

A block fits one PCB, not one chip, and the Astral block is named for a specific card line, so confirm your exact card against the block maker’s compatibility list before ordering. A block does not move to a new card, so a card upgrade means a new block. wikiHow’s advice is to design the whole system before buying, because sending parts back is slow and costly, and it recommends a case of at least ATX mid-tower size.

Radiator area for a CPU plus GPU: the sourced rule against a 640mm layout

formulamod gives the standard rule as 120mm of radiator per 100W of TDP, plus an extra 120mm of headroom. That is 1.2mm per watt plus 120mm. Method: we calculated what that rule asks for on one example layout and three example heat loads, so every figure here is our own arithmetic, not a measurement. A layout with a 360mm and a 280mm radiator is 640mm in total, which the rule covers up to (640 minus 120) divided by 1.2, about 433W of combined heat.

Heat loadRule: 1.2mm per W plus 120mmAgainst the 640mm layout
150W CPU alone300mmCovered
400W (150W CPU plus 250W GPU)600mmCovered
650W (150W CPU plus 500W GPU)900mmShort by 260mm

With a 150W CPU, the 640mm layout leaves room for a GPU of only about 283W (433 minus 150), so a high-power card needs more radiator than this example. The rule already carries 120mm of headroom, and radiator makers’ own rating sheets are the other input if you want to size tighter. If your numbers exceed what the case holds, the options are a larger radiator, a lower power limit on the card, or keeping the GPU on air and running a CPU-only loop, which is the thin case described above.

Check the case before you check anything else: a 360mm mount plus a 280mm mount, as in the example layout. Measure RAM clearance against a front or top radiator using the module height on the memory maker’s spec sheet.

Steps 1 to 6: the choices to settle before anything ships

Step 1 and Step 2: layout and radiators

This guide’s loop is a single series circuit. The order used here is reservoir, pump, radiator one, CPU block, GPU block, radiator two, and back to the reservoir. Keep the runs free of sharp bends, because kinks strain the pump (wikiHow). Sketch the case from the side, place the pump and reservoir low, and mark each radiator mount. Radiator choice is the sizing work in the previous section.

Step 3: pump and reservoir

formulamod recommends the D5 for most builds: its flow rate copes with several blocks and radiators, and it runs near-silent at 60-70% PWM. The DDC suits compact builds where restriction is high, because its head pressure pushes coolant through tight micro-fin blocks. formulamod’s pump table, as it read when checked on November 13, 2026, puts numbers on the trade.

SpecificationD5DDC
Max flow rate1500 L/H1000 L/H
Max head pressure3.9m5.2m
Noise levelQuieterLouder at full speed
SizeLarger (100mm tall)Compact (62mm tall)

For a two-radiator, two-block loop the D5 is the default here: it has the higher flow and is the quieter of the two, and the cost is its 100mm height, so check that the reservoir and case have room for it. Buy a pump and reservoir combo with a spare port, because Custom PC attaches its leak tester to a spare reservoir port so the whole loop is tested without dismantling anything. formulamod puts the minimum practical reservoir at about 100ml, since smaller ones make bleeding slow, and Syber Gaming says to ensure the pump is below the reservoir to prevent air bubbles.

Step 4: blocks and threads

The CPU block must match your socket and the GPU block must match your exact card, as covered above. On threads, Alphacool’s product page says its G1/4 screw-on connector is compatible with 95% of all components, so G1/4 is the thread to expect. Check each block, radiator and reservoir before ordering fittings rather than assuming that parts from different brands are interchangeable.

Step 5: soft tubing for a first loop

wikiHow recommends flexible tubing for first-timers because it is more forgiving of mistakes, and this guide builds with soft tubing for that reason. A wrong run can be rerouted and retried. Kinked tubing cuts performance and strains the pump, according to wikiHow, so plan each run without tight bends.

On sizes, formulamod’s beginner-mistakes page, as it read when checked on November 13, 2026, lists standard soft tube as 10x13mm (3/8″ ID x 1/2″ OD) and 10x16mm (3/8″ ID x 5/8″ OD), and standard hard tube as 12mm, 14mm and 16mm OD. Settle the tube size first, then order fittings made for that size.

Step 6: tubing length and fittings

Measure each run along the real case interior with string, in loop order, then add a margin for the length that disappears inside each fitting. Count the ports on your own blocks, radiators, pump and reservoir before ordering, because every port needs a fitting or a plug, and add a drain valve fitting for the lowest point of the loop. Buy a few spare fittings in case one is damaged during install.

Steps 7 to 10: mounting and plumbing, and the mistakes that damage hardware

Tools: Phillips and Torx screwdrivers, hex keys for block hardware, a tubing cutter, string or calipers for measuring, a funnel with scrap tubing, isopropyl alcohol, paper towels and nitrile gloves.

Step 7, mount the hardware. Empty the case, or pull the motherboard if the case allows. Fit fans to each radiator first, then mount each radiator and fan assembly as one unit. Install the pump and reservoir low, using its bracket, and route fan, pump and RGB power cables now, before tubing blocks the connectors.

Step 8, install the blocks. Clean the CPU heat spreader with isopropyl alcohol and apply paste. wikiHow’s guidance is a single rice grain’s worth. Mount the CPU block with its socket backplate and tighten the screws incrementally in a cross pattern, because uneven pressure can damage the CPU. For the GPU, check your card maker’s warranty terms before removing the stock cooler, clean the die and every pad location, and use fresh pads of the thickness the block’s manual specifies. Wrong pad thickness or a block that is not fully seated shows up as high GPU temperatures beside normal CPU temperatures. Install the card in its slot only after the block is seated and inspected.

Step 9, cut and route tubing. Cut soft tubing square with a dedicated cutter, because a ragged end will not seal in the fitting, and push it fully onto the fitting before tightening the collar. Test-fit every run dry first, and route clear of fan blades, RAM and case standoffs, since kinks cut flow and strain the pump.

Step 10, tighten and cap. Hand-tighten each compression collar until it stops, using light finger pressure and not a wrench, and follow the fitting maker’s instructions for any further turn. Confirm that every port on every block, radiator and the reservoir has a fitting or plug, because a port left open floods the case on the first fill. Fit the drain valve at the lowest point now.

Steps 11 and 12: fill, bleed, then leak-test in three stages

The leak test here runs as three stages: an air-pressure test at 0.3 bar, a fill-and-bleed run, and a filled soak. The pressure test is fast and needs no coolant; the filled stages find what air cannot.

StageSetupDurationWhat it finds
Stage 1: air pressureNo coolant; tester on a spare reservoir port; whole loop raised to 0.3 barTen minutesLoose fittings, shown as a falling gauge
Stage 2: fill and bleedCoolant in; pump powered alone, board and GPU unpowered; look at each fitting while it runsUntil the loop runs quiet, with the level checked every hourAir pockets, first seeps
Stage 3: soakSame isolation; paper towels under every fitting and blockLonger for a first loop (this guide’s protocol)Slow seeps

Custom PC’s figure is 0.3 bar, which it calls more than enough pressure to find any leaks. Its ten-minute hold is long enough for a loose fitting to show as a dropping gauge. A 2005 PCPer review of a Koolance system makes the same point at the other end: leak-test the assembled system before powering up the computer. The air test is cheap enough that nothing should skip it, but it cannot replace the soak, because the soak runs real coolant through the loop for hours. The soak is this guide’s own conservative protocol and its length is not a sourced figure; give a first loop the longer end of what your own risk tolerance allows.

Filling. Use distilled water or a premixed coolant, which Syber Gaming says prevents corrosion and algae growth. wikiHow says never to use tap water, because its mineral content can damage the system. Keep the motherboard and GPU unpowered and run the pump alone from the power supply, after reading how to test a power supply first. Run the pump, stop it, and top off the reservoir as air leaves the lines, as the PCPer review describes.

Bleeding. Custom PC’s advice is to speed the pump up to shift bubbles, or slow it down to help trap air in the reservoir, and to tilt the system if that does not move them. The coolant level falls as air collects in the reservoir, so inspect it every hour and top up. Air left in the loop makes the PC noisier than an air-cooled one, which defeats the build.

Soaking. Line the case floor with paper towels and look under each fitting and block. A damp spot means a leak at that joint: drain, reseat or retighten it, and restart Stage 3 from zero. Do not reconnect motherboard, CPU or GPU power until a full soak finishes dry.

Step 13: first boot, a fixed pump speed, a fan curve and a logger

Reconnect power, close the case and boot into BIOS before the operating system. If the CPU temperature reading is absent or implausible at idle, shut down and recheck the CPU block seating. Then tie the radiator fans to coolant temperature, and hold the pump at a fixed speed, roughly 65% for a D5, inside the 60-70% PWM band where formulamod says it runs near-silent.

Run a CPU stress test and a GPU-bound load while watching temperatures. A healthy loop plateaus; if temperatures climb steadily, revisit radiator sizing or look for an airlock. If you plan to overclock the GPU, expect the extra heat to land in this loop. The logger below suits watching temperatures during burn-in. The loggers write one temperature reading per sensor at a fixed interval, set by the sleep line, to a CSV file. They run only once the operating system is up, so they suit this burn-in, not the powered-off soak. The Windows version reads the root/LibreHardwareMonitor namespace, so it needs that monitor running; the Linux version uses the sensors command.

# Burn-in logger (Windows PowerShell): run after Windows boots; stop with Ctrl+C
$dir = "C:\LoopLogs"
New-Item -ItemType Directory -Path $dir -Force | Out-Null
$logFile = Join-Path $dir ("burnin_{0}.csv" -f (Get-Date -Format "yyyyMMdd_HHmm"))
"Timestamp,SensorName,Value" | Out-File $logFile -Encoding utf8

try {
    while ($true) {
        $stamp = Get-Date -Format o
        $sensors = Get-CimInstance -Namespace "root/LibreHardwareMonitor" -ClassName Sensor |
            Where-Object { $_.SensorType -eq "Temperature" }
        foreach ($s in $sensors) {
            '"{0}","{1}",{2}' -f $stamp, $s.Name, $s.Value |
                Out-File $logFile -Append -Encoding utf8
        }
        Start-Sleep -Seconds 60
    }
}
finally {
    Write-Host "Logging stopped. File: $logFile"
}
#!/bin/sh
# Burn-in logger (Linux): run after the OS boots; stop with Ctrl+C
mkdir -p "$HOME/loop-logs"
log="$HOME/loop-logs/burnin_$(date +%Y%m%d_%H%M).csv"
echo "timestamp,sensor,value_c" > "$log"

while true; do
  stamp=$(date -Iseconds)
  sensors -u | awk -v t="$stamp" '
    /^[^ ].*:$/ { name = $0; sub(/:$/, "", name) }
    /temp[0-9]+_input:/ { print t ",\"" name "\"," $2 }' >> "$log"
  sleep 60
done

If gurgling returns after first boot, repeat the Stage 2 bleeding steps.

Symptoms, causes and the coolant refresh routine

SymptomLikely causeFix
Gurgling or rattlingAir near the pump inletTilt the case gently, run the pump longer to work bubbles toward the reservoir
Damp spot under a fittingUnder-tightened fitting or poorly seated O-ringDrain that section, reseat the tube fully, hand-tighten with light finger pressure, restart the soak
CPU temperatures normal, GPU highGPU block not fully seated, or wrong pad thicknessReseat the block and fit pads of the correct thickness
Level drops slowly over weeks, no visible leakSlow loss: evaporation, or a seep too small to show during the soakCheck under every fitting with a dry paper towel, then top off with distilled water
Cloudy or discolored coolantAlgae, or a reaction between coolant and metal or tubingDrain, flush with distilled water, refill with fresh coolant plus biocide
Pump runs, flow indicator shows nothingAirlock, often at the highest pointPower-cycle the pump, tilt the case to move the air toward the reservoir
White or green residue on fittingsCorrosion, or mineral deposits from the wrong waterDrain and inspect, replace the corroded fitting, refill with distilled water or premix, never tap water
No boot after reassemblyRAM or GPU disturbed during block install, or a power cable left offReseat RAM and GPU, trace every power cable back to the PSU
  • Routinely: check the reservoir level and top off with distilled water.
  • At each refresh: follow the interval printed for your coolant, drain from the valve at the lowest point, flush with distilled water, refill, and bleed again as in Stage 2.
  • If you mix your own coolant from distilled water, add biocide and corrosion inhibitor at every refill.
  • Card upgrade: a new card needs a new GPU block (Corsair lists its 5090 Astral block at $389.99), while the pump, reservoir, radiators and fittings carry over; rerun all three leak-test stages.
Sofia Lindström

Sofia Lindström

Security and privacy

Sofia Lindström writes about security and privacy for Tech Insider: software vulnerabilities and the updates that fix them, data breaches, privacy rules and how products handle personal data. She works from vendor advisories, official vulnerability catalogues and the documents behind each story.

View all articles